TM 1-6625-476-30
3-28
3-11. PNVS NSA INSTALLATION ON NIGHTSIDE TEST BENCH. (CONT)
g. Cooling. Assemble the cooling adapter, if necessary. Attach the cooling air hose to the cooling air
outlet and to the cooling adapter. Adjust the adapter to direct the cooling air onto the cooler/dewar
(figure 3-30).
3-12. PNVS NSA REMOVAL FROM NIGHTSIDE TEST BENCH.
This paragraph covers the steps required to remove the PNVS NSA from the nightside test bench and
place it in the shipping and storage container.
a. Cooling. Remove the cooling air hose from the cooling air outlet and the cooling adapter. Remove
and stow the cooling adapter.
b. Pneumatic System Shutdown. Perform pneumatic system shutdown according to paragraph
3-11d.
c. PNVS NSA Removal from Nightside Test Bench.
NOTE
Two people are required to perform this task.
(1) Disconnect following connectors of cable assembly 13083693-19:
P3 from P1 of PNVS NSA
P4 from J1 of PNVS NSA
P5 from terminal box
P6 from J4 of PNVS NSA