TM 1-6625-476-30
2-27
2-11. TADS NSA INSTALLATION ON NIGHTSIDE TEST BENCH. (CONT)
Figure 2-18. Bleed/Drain Valve Location
(7) On nightside test bench, close door (3, figure 2-15). Push and rotate turnlock fasteners (2)
1/4 turn clockwise.
(8) Verify that E/O test bench set is floating, and not banging or bottoming out. If it is, refer to TM
11-6625-3081-23-4.
2-12. CHANNEL BALANCE ADAPTER INSTALLATION.
This paragraph covers the steps required to shut down the pneumatic system, remove the TADS NSA
from the nightside test bench, remove the insert/adapter from the TADS NSA, install the channel balance
adapter on the TADS NSA, and reinstall the TADS NSA on the nightside test bench.
a. Pneumatic System Shutdown. Perform pneumatic system shutdown according to paragraph
2-11a.
b. TADS NSA Removal from Nightside Test Bench.
(1) Disconnect the following cables:
(a) P3 of cable 13083693 from P1 on TADS NSA.
(b) P4 of cable 13083693 from J2 on TADS NSA.