TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
CLEAN AND REPLACE AUXILIARY PUMP INLET COMPONENTS
Materials/Parts Required:
INITIAL SET-UP:
Tools:
Tool Kit, General Mechanic Automotive
Equipment Condition
Auxiliary pump module defueled
Chemical and Oil Protective Gloves
WARNING
Death or personal injury may result from the explosion of fuel fumes exposed to an open flame or
spark, or to static discharge. Do not permit smoking, any open flame, or spark producing equipment
within fifty (50) feet (15.24 m) of the auxiliary pump during repair.
NOTE
Even with the auxiliary pump defueled, some residual fuel may remain due to normal drainage after
Inspect all components as they are disassembled. Repair is limited to replacement of unserviceable
components discovered during disassembly.
DISASSEMBLY AND INSPECTION
1.
Remove the four bolts (1) that attach inlet flange (2) to pump housing (3).
2.
Remove and clean inlet screen (4).
3.
Remove and discard inlet flange gasket (5).
ASSEMBLY
1.
Position inlet flange gasket (5) on pump housing (3).
2.
Position inlet screen (4) on pump housing (3).
3.
Install inlet flange (2) on pump housing (3) using the four bolts (1).
0072 00-1