TM 55-2840-231-23
6-15. Fuel Pump - Removal - Continued
ENGINE/ - Continued
7. Pump and Plate
8. Gasket (11) and
Reformed Pecking
(9)
Remove pump and plate
from mounting studs.
Remove and discard
mounting flange gasket
(11 ) and preformed
packing (9).
If a new pump is to be installed, remove the
tube fittings and keep them for installation
in the new pump. Discard the preformed
packings.
6-16. Fuel Pump - Installation
INITIAL SETUP
Applicable Configuration
Consumable Materials
All
Lubricating Oil (item 5, Appendix D)
Lubricating Oil (item 4, Appendix D)
References
Para 1-63 thru 1-71
If a new pump is to be installed, transfer
tube fittings from removed pump to new
pump. Use new preformed packings lubri-
cated with oil (item 4, Appendix D).
Tighten fittings in inlet, discharge, and
bypass ports to 75-110 in. lb (0.9 -1.3
kg/m). Tighten fittings in the before-filter,
after-filter, and seal drain ports to 55-80
in. lb (0.6 -0.9 kg/m).
6-34