2-39 REPAIR AIR DIFFUSER ASSEMBLY (AVIM) (Continued)
2-39
2. Wear goggles. Clear contaminated oil passages
(2 and 3) as follows:
a. Remove No. 2 bearing pressure oil strainer
(Ref. Task 8-76).
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than
30 psig air pressure. Do not direct air
toward yourself or another person.
Failure to comply could result in in-
jury to eyes or skin. In case of injury,
get medical attention.
b.
c.
Apply compressed air to tube ends (4). Use
clean, dry compressed air. Feel for air flow
at scavenge adapter (5) and pressure line
connector (6).
Clean No. 2 bearing pressure oil strainer
(Ref. Task 8-77).
Install No. 2 bearing pressure oil strainer
(Ref. Task 8-79).
GO TO NEXT PAGE