2-7 INSTALL INTERSTAGE AIR-BLEED ACTUATOR (WITHOUT WATER WASH KIT
2-7
P/N 2-200-071-54 INSTALLED) (Continued)
3. Hold interlock parts together and position
them so bleed band upper end (4) is seen
through slot (69.) install pin (7).
4. Interlock bleed band lower end (8) and tangs of
yoke (9). Hold interlocked parts together and
position them out of bracket (10). Install pin
(11).