TM 55-2840-254-23
2-8 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITHOUT WATER WASH KIT
2-8
P/N 2-200-071-54 INSTALLED) (Continued)
16. Place finger over union (15). Check clearance
between bleed band (21) and compressor
housing (19) at 12-,5-, and 8-oclock posi-
tions. Use thickness gage. Clearance shall not
be more than 0.002-inch drag fit. If fit is too
loose, proceed as follows:
a. Check bleed band (21) for twists. kinks.
GO TO NEXT PAGE
and dirt or other deposits on side that goes
against compressor housing (19). Replace
bleed band (21) if twisted or kinked (Ref.
Task 2-9 and 2-13).
Change 5
2-35