TM 5-2840-254-23
4-32 INSTALLTHIRD TURBINE NOZZLE AND SUPPORT (AVIM) (Continued)
4-32
NOTE
Clearance required is 0.101 inch
minimum.
i. Subtract Dimension F from Dimension C to
determine clearance between third turbine
nozzle (7) and third turbine rotor (15). Record
as Dimension G.
Select shim from shim selection table to
obtain 0.101 inch minimum. Use outside
micrometer caliper.
Example: If Dimension G IS 0.090 inch, select
shim Part No. 2-141-148-01. If Dimension G is
0.070 inch, select Shim Part No.
2-141-148-02. If Dimension G is 0.050 inch
select Shim Part No. 2-141-148-03.
GO TO NEXT PAGE
4-148.4
Change 2