TM 55-2840-254-23
3-5
REMOVE COMBUSTION SECTION AND POWER TURBINE (AVIM) (Continued)
3-5
When discharging ignition exciter, only
one lead shall be removed at a time and
receptacle that lead was removed from
shall be discharged. Failure to comply
may result in serious shock when you
are removing second lead. In case of
serious shock get medical attention.
NOTE
Steps 3. and 4. apply to both output
receptacles.
3. Remove lockwire and disconnect ignition coil
and cable assembly leads (7).
4. Discharge ignition exciter (8) by placing tip of
insulated screwdriver (9) against pin (10) and
edge (11) of receptacle (12).
5. Place ignition coil and cable assembly leads (7)
to one side.
GO TO NEXT PAGE
3-14