fig. 5-1.
TM    55-4920-428-13
c. Push connector through panel for access to pins.
d. Tag  and  disconnect  wires  per  TM  55-1500-323-25.  Use  insertion/extraction  tool.  Inspect  pins  for
damage and replace as required. Connect pins to replacement connector.
e. Install replacement receptacle in panel. Install retaining nut.
f. Perform  an  operational  check.  (Ref  para  5-18.)
g. Install  panel  in  case.  (Ref  para  5-45.)
5 - 4 1 .     R e p l a c e m e n t     o f     S O L E N O I D     S w i t c h
e.
a.
b.
c.
d.
f.
g.
h.
i.
(See fig. 6-4.) Remove the panel from the case. (Ref para 5-22.)
Tag and disconnect five wires from the switch (52).
Unscrew switch knob (51). Remove the locknut and washer from the switch.
Remove the switch contact block.
Position  the  replacement  on  the  panel.  Install  the  washer  and  locknut.
Install  the  switch  knob.
Connect  the  five  wires  to  the  switch.
Perform  an  operational  check.  (Ref  para  5-18.)
Install  the  panel  in  the  case.  (Ref  para  5-45.)
5 - 4 2 .      L u b r i c a t i o n
.
Refer  to  para  3-5.
5-43.   Flow   Limiter   and   RELIEF   VALVE   Adjustment.
a.
b.
c.
d.
f.
g.
(See fig. 5-1.) Prepare the unit for use. (Ref para 2-6.)
Perform  self-test  procedures.  (Ref  para  2-7.)
Remove the hydraulic unit panel from the case. (Ref para 5-22.)
Perform  fill  and  bleed  procedures.  (Ref  para  2-8.)
Perform high pressure self-test. (Ref para 2-9.)
Check  that  switches  and  valves  are  at  initial  settings.  (Ref  tables  2-1  and  2-2.)
Set the electrical unit power switch to ON. Check that the LAMP TEST switch POWER lamp
se.
5-1
3