TB 1-1730-229-20-2
Add the following between AC voltage output and AC power output:
Part Number 83-360A:
Add the following just before pneumatic output:
Part Number 83-360D:
AC power output:
38.4 KW (48.0 KVA) continuous
30.0 KW (37.5 KVA) continuous with 250 amperes 28 VDC output from the TRU
66.0 KW (82.5 KVA) for 30 seconds
DC power output:
250 amperes continuous at 26 volts minimum
350 amperes continuous at 25 volts minimum
500 amperes for 1 minute
1000 amperes for 5 seconds
Change "Noise Level" to read as follows:
Noise Level. Less than:
85
dBA at 23 foot (7 meter) radius
90/93
dBA at operator panel
103/105
dBA at GTE air inlet
5. Generator and Generator Control Unit (GCU). Revise remainder of page 1-20 to read:
Manufacturer:
Leland Electrosystems
Smiths Industries, Aerospace
(CAGE 07639)
P/N 83-360A:
AGH 815-1 (Generator)
Rated-continuous duty, single mode
AC 30 KW, 3 phase, 400 Hertz, 115/200V,
0.8 power factor
DC 700 amperes, 28 vdc
P/N 83-360D:
AGH 828-3 (Generator)
5