NAVAIR 01-1A-505-2
003 03
TO 00-25-255-1
Page 23
TM 1-1500-323-24-2
27. Straight Strain Relief M85049/45. These are straight
c.
Remove strain relief using tools and tool
nonmetallic strain reliefs. The strain relief, along with
procedure for backshell removal (paragraph 21).
dimensions and part number breakdown, is illustrated
(Figure 17).
d. Perform connector repair per NAVAIR 01-1A-
505-1.
28. Straight Two Piece Strain Relief M85049/64. This
is a straight two piece strain relief. The strain relief,
36. CABLE CLAMP-TYPE STRAIN RELIEF INSTAL-
along with dimensions and part number breakdown,
LATION. Upon the completion of connector repair
is illustrated (Figure 18).
install the strain relief using the following procedure
(Figure 25):
29. Straight Quick-Tie (Cancelled) M85049/56. This is
a Straight Quick-Tie strain relief . The strain relief,
a. Wrap cable with reinforcing silicone tape to
along with dimensions and part number breakdown,
build cable diameter where necessary.
is illustrated (Figure 19).
b. Install strain relief using tools and tool
30. 45 Quick-Tie Strain Relief (Cancelled) M85049/57.
procedure for backshell installation (paragraph 22).
This is a 45 Quick-Tie strain relief. The strain relief,
along with dimensions and part number breakdown,
c.
Restore proper dress of wire at connector. Wire
is illustrated (Figure 20).
should not elongate grommet holes, pull tightly, or be
kinked (Figure 26).
31. 90 Strain Relief (Cancelled) M55049/47. This is a
90 strain relief The strain relief, along with dimensions
d. Tighten screws in saddle clamp to provide firm
and part number breakdown, is illustrated (Figure 21).
gripping action preventing wire movement without
damage or crushing.
32. 90 Strain Relief M85049/46. This is a nonmetallic
90 strain relief. The strain relief, along with
37. QUICK-TIE STRAIN RELIEFS. Quick-Tie strain
dimensions Find part number breakdown, is
reliefs are installed with lacing tape securing the wires
illustrated (Figure 22).
instead of saddle clamps. The use of this type
eliminates frequent tape wrapping to alter cable
33. 90 Two Piece Strain Relief M85049/65. This is a
90 two piece strain relief. The Strain relief, along with
dimensions and part number breakdown is illustrated
38. QUICK-TIE STRAIN RELIEF REMOVAL. When
(Figure 23).
connector repair is necessary remove the Quick-Tie
strain relief using the following procedure:
34. 90 Quick-Tie Strain Relief M85049/63. This is a
90 Quick-Tie strain relief. The strain relief, along with
a.
Cut lacing tape securing cable or wires to strain
dimensions and part number breakdown, is illustrated
relief.
(Figure 24).
b. Remove strain relief using tools and
35. CABLE CLAMP-TYPE STRAIN RELIEF REMOV-
procedures for backshell removal (paragraph 21).
AL. To remove this type of strain relief use the follow-
ing Procedure (Figure 25):
c.
Perform connector repair.
a.
Loosen saddle clamp screws.
b.
Unwrap any reinforcing silicone tape.