NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 02
1 September 2011
Page 21
45. TRIAXIAL CONTACTS. Triaxial contacts are
used to interconnect double shielded, cable similar to
48. QUADRAXIAL CONTACTS. Quaderaxial
coaxial cable with an additional intermediate shield and
contacts are used to interconnect four conductors in an
for the EPX series of inserts shielded, twisted pair cable
overall shielded cable (Ethernet or Quad) contacts are
is also connected as listed Table 5.
listed in Table 6.
46. Cable And Triaxial Contact Assembly. To assemble
49. Cable And Quadraxial Contact Assembly. To
the triaxial contact to the applicable cable select the
assemble the quad axial contact to the cable, select the
proper contact (Table 5). Select the proper tooling
proper contact (Table 6). Select the proper tooling
required (Table 5).
required (Table 6).
47. Strip the cable to the dimensions specified in Figure
50. Strip the cable to the dimensions specified in Figure
36 thru 41, according to the stripping procedures in
42 and 43, according to the stripping procedures in
NAVAIR 01-1A-505-1, WP 009 00. Build-up crimp
NAVAIR 01-1A-505-1, WP 009 00. Build-up crimp
tools as specified in Table 5, according to NAVAIR 01-
tools as specified in Table 6, according to NAVAIR 01-
1A-505-1, WP 013 00. The contact is assembled using
1A-505-1, WP 013 00. The contact is assembled using
the procedures in Figure 36 thru 41.
the procedures in Figure 43 and 44.