TM 1-1520-264-23
4.6.3.5 NDI Equipment Settings.
a.
Make the following initial settings on the Eddy Current Inspection Unit, NORTEC-1 9e".
Frequency F1
- 200 KHz
F2
- off
HdB
- 57.0
VdB
- 69.0
Rot
- 56°°
Probe drive - mid
LPF
- 100
HPF
-0
H Pos
- 80%
VPos
- 20%
b.
Refer to Eddy Current Method, paragraph 1.4.11. Set up on test block as follows:
(1) Null probe on test block.
(2) Adjust phase as required to obtain horizontal lift-off.
(3) Move probe over all three notches in test block. Adjust gain to obtain a three block vertical signal when probe
is passed over 0.040-inch notch in test block. (See the standard instrument display shown in Figure 1-7.)
4.6.3.6 Inspection Procedure. Refer to Eddy Current Method, paragraph 1.4.11 and Figure 4-6.
Figure 4-6. Transmission Deck
4-17