TM 1-1520-264-23
Figure 6-17. CPG Cyclic Stick Remote Control Lever
6.18 CPG CYCLIC STICK FITTING ASSEMBLY (ET).
6.18.1
Description (Figure 6-1. Index No. 18). The CPG cyclic stick fitting assembly is at the base of the cyclic stick and
connects the cyclic stick to the cyclic adjust lock assembly. Inspect the fitting assembly, the cyclic adjust lock assembly,
and the CPG cyclic stick.
6.18.2
Defects. This inspection is used to verify crack indications found visually on the CPG cyclic stick fitting
assembly. No cracks are allowed.
6.18.3
Primary Method. Eddy Current.
6.18.3.1 NDI Equipment and Materials. (Refer to Appendix B.)
a.
Eddy Current Inspection Unit
b.
Probe, straight, shielded surface, 100 KHz-500 KHz
c.
Probe, right angle, shielded surface, 100 KHz-500 KHz, 90 °
1/2 inch drop
d.
Cable Assembly
e.
Reference Block, three-notched aluminum (0.008, 0.020, and 0.040 EDM notches)
f.
Teflon Tape, refer to Table 1-8
g.
Aircraft Marking Pencil, refer to Table 1-8
6-38