TM 1-4920-435-13&P
0022 00
WATER FEED-THRU CONNECTOR ASSEMBLY
Inspect
1. Check condition of threads on both ends of water feed-thru connector (2).
2. See that protective dust caps (1) are attached and used as required.
3. Ensure that weld (3) on connector (2) is not cracked or broken. If defective, replace.
0022 00-3