TM 1-4920-436-13&P
0018 00
NOTE
Receptacle lugs are identified by letters "X", "Y", and "Z" with ground connection
being identified by color green. Black wire will be attached to "X", red wire will be
attached to "Y", and blue wire will be attached to "Z".
3. Replace wires and tighten all lugs on 60A receptacle.
4. Replace 60A receptacle.
5. Install four machine screws to attach 60A receptacle to 54 degree adapter housing.