TM 1-4920-436-13&P
0025 00
CONNECTOR PLUG, 20A, 240V, 1PH
Inspect
With the 240V connector plug unplugged, visually inspect the 240V connector plug for any damage that could
possibly cause an electrical hazard.
CAUTION
This work should be performed by a qualified electrician!
Test
Using a multimeter, check for continuity. If an electrical problem is discovered, replace the 240V connector plug.
Remove
1. Loosen two screws from body of 240V connector plug housing.
2. Loosen three screws from face of 240V connector plug.
3. Pull 240V connector plug apart and disconnect wires from "X", "Y", and ground terminals.
0025 00-11