TM 10-4930-351-14
0006 00
Table 1. Operator's Preventive Maintenance Checks and Services for AAFARS
Item Interval
Location
Procedure
Not Fully Mission
No.
Capable If:
Item to Check/
Service
WARNING
Fuel fumes are always present in the vicinity of
the AAFARS. Death or personal injury may
result from the explosion of fuel fumes exposed
to an open flame or spark. Do not permit any
smoking, any open flame, or spark producing
equipment within fifty (50) feet of the
AAFARS.
Be sure the flex coupling guard is in place.
Death or personal injury may result from
contact with rotating parts.
1
Before All Ground
Inspect ground cables for cuts, breaks or loose connections.
Cuts, breaks or
Cables
loose connections
make ground cable
unusable.
2
Before All Unisex
Remove dust cap (1), depress continuity ball (2) on valve seat,
Continuity ball
release and observe that ball pops back out. If ball does not pop
does not pop back
back freely, electrical continuity is lost and static discharge is
out.
possible. The coupling must be replaced. Notify unit maintenance.
1
2
3
Before System
Inspect for physical damage that might prevent successful
Physical damage
operation.
will not allow
normal operation of
module.
4
Before Fire
Inspect for fully charged bottles (gauge reading in green area).
Fire extinguishers
Extinguishers
are not fully
charged.
0006 00-2