TM 55-2840-254-23
NOTE
Steps 6. and 7. apply to connectors at
each end of air gallery cover lower half
(3- and 9-oclock positions). Connector
at 3-oclock position is shown.
2-18 INSTALL ANTI-ICING AIR GALLERY COVER (Continued)
2-18
When installing nuts on connector, en-
gage about two threads only,
6. Install two retainers (18), spacers (19), and
nuts (20) on connector (21).
7. Install connectors (21) on ends of air gallery
cover lower half (13).
8. Torque 23 bolts (17) to 85 inch-pounds and
Iockwire. Use Iockwire (E29).
GO TO NEXT PAGE
2 - 6
7