TM 55-2840-254-23
Section I. INTERSTAGE AIR-BLEED ACTUATOR - MAINTENANCE PROCEDURES
2-1
REMOVE INTERSTAGE AIR-BLEED ACTUATOR-MAINTENANCE PROCEDURES
P/N 2-200-071-54 INSTALLED
2-1
INITIAL SETUP
Equipment Condition:
Oil Cooler Assembly Removed (Task 8-5
Applicable Configurations:
All
General Safety Instructions:
Tools:
Powerplant Mechanic's Tool Kit,
NSN 5180-00-323-4944
Materials:
None
Personnel Required:
The ignition exciter stores very high and
possibly fatal voltage. Use extreme care
when working around ignition exciter.
Serious injur could result if exciter is
accidentally grounded. Do not probe inside
of putpit receptacles with fingers or metal
object. Discharge exciter only with insulated
screwdriver. In case of shock or injury, get
medical attention
68B10 Aircraft Powerplant Repairer
GO TO NEXT PAGE
Change 5 2-5