TM 55-2840-254-23
2-1.1 REMOVE INTERSTAGE AIR-BLEED ACTUATOR (WITH WATER WASH KIT
P/N 2-200-071-54 INSTALLED)(Continued)
2-1.1
When discharging ignition exciter, remove
one lead at a time and discharge receptacle
that lead was removed from. Failure to do so
may result in serious shock when you are
removing second lead. In case of serious
shock, get medical attention.
1. Remove nut (1) and screw (2)
NOTE
Steps 2. and 3. apply to both output receptacles.
2. Remove lockwire and disconnect coil and cable
assembly leads (3).
3. Discharge ignition exciter (4) by placing tip of
insulated screwdriver (5) against pin (6) and edge
(7) of receptacle (8).
4. Place leads (3) to one side.
GO TO NEXT PAGE
Change 5 2-12.1