2-52 INSTALL OUTPUT SHAFT SEAL AND HOUSING ASSEMBLY (Continued)
2-52
2. Prepare shim (4) as follows:
a. Peel off layers (5) as required to obtain shim
thickness required.
b. Measure thickness of shim (4) and check
against shim selection table. Use outside
micrometer caliper.
INSPECT
3. Install packing (6) in groove (7) on output shaft
seal housing assembly (8).