TM 55-2840-254-23
2-3 CLEAN INTERSTATE AIR-BLEED ACTUATOR
2-3
INITIAL SETUP
Applicable Configurations:
All
Tools:
Goggles
Compressed Air Source
Materials:
Dry Cleaning Solvent (El 7)
Gloves (E20)
Lint-Free Cloth (E26)
Personnel Required:
68B10 Aircraft Powerplant Repairer
Equipment Condition:
Off Engine Task
Oil Cooler Assembly Removed (Task 8-5)
Interstage Air-Bleed Actuator Removed
(Task 2-1 )
Interstage Air-Bleed Actuator Disassembled
(Task 2-2)
General Safety Instructions:
1
Dry cleaning solvent (E17) is flam-
mable and toxic. It can irritate skin
and cause burns. Use only in well-
ventilated area, away from heat and
open flame. In case of contact, im-
mediately flush skin or eyes with
water for et least 15 minutes. Get
medical attention for eyes.
1. Wear gloves ( E20). Clean interstage air-bleed
actuator (1) with Iint-free cloth (E26) dampened
in dry cleaning solvent (E17).
GO TO NEXT PAGE
2-14