TM 55-2840-254-23
2-80.16 INSTALL CHECK VALVE (WATER WASH TEE TO INTERSTAGE
2-80.16
AIR-BLEED ACTUATOR P3 INLET) (Continued)
7.
8.
9.
Install bolt (8] on clamp (4).
Using bolt (8), secure check valve (3) to bleed
band retainer (9).
Torque tilt (8) to 65 inchpounds.Lockwire
bolts. Use lockwire (E29).
INSPECT
GO TO NEXT PAGE
C h a n g e 5
2-556.47