TM 55-2840-254-23
Section VI. COMBUSTION CHAMBER HOUSING - MAINTENANCE PROCEDURES
3-19 CLEAN COMBUSTION CHAMBER HOUSING (AVIM)
3-19
INITIAL SETUP
Applicable Configurations:
All
Tools:
Compressed Air Source
Fiber Brush
Goggles
Materials.
Gloves (E20)
Methyl Ethyl Ketone (E36)
Personnel Required:
68B10 Aircraft Powerplant Repairer
Equipment Condition:
Off Engine Task
Engine Oil System Drained (Task 1-75)
Combustion Section and Power Turbine
Removed (Task 3-5)
Combustion Section and Power Turbine
Disassembled (Task 3-6)
Combustion Section Disassembled (Task 3-9)
Methyl ethyl ketone (E36) is flammable
and toxic, It can irritate skin and cause
burns. Use only in well-ventilated areas,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
1, Clean combustion chamber housing (1) as fol
lows.
a. Wear gloves (E20) and goggles. Use methyl
ethyl ketone (E36) and fiber brush.
GO TO NEXT PAGE
3-213