4-19 INSTALL FIRESHIELD SECTION (Continued)
4-19
Reducer must be held with wrench
when connecting hose assembly. Failure
to comply will cause damage to internal
tube assembly.
8. Hold reducer (10) with wrench. Connect hose
assembly (14) to reducer (10).
INSPECT
FOLLOW-ON MAINTENANCE:
Install Left- and Right-Hand Fuel Manifold
Assemblies (Task 6-20).
Install Fireshield Assembly (Task 4-15).
Install Left- and Right-Hand Bus Bar Assemblies
(Task 4-11).
Install Tube Assembly (No. 4 and 5 Bearing
Scavenge Connector to Hose Assembly)
(Task 8-57),
Install Exit Vane Assembly (Task 4-82).
END OF TASK
4-96