TM 55-2840-254-23
4-44
INSTALL NO. 4 AND 5 BEARING OIL TUBES (AVIM) (Continued)
4-44
i. Apply anti-seize compound (E5) to 19 bolts
(20). Install 19 bolts (20).
j. Lockwire bolts (20). Use lockwire (E29).
k. Install No. 4 and 5 bearing oil pressure tube
adapter (21) at 12-oclock position as follows:
(1)
Install adapter (21) on tube assembly (2).
Tighten nut (22) finger tight.
GO TO NEXT PAGE
4-260