4-49 INSTALL FOURTH STAGE POWER TURBINE NOZZLE (AVIM) (Continued)
4-49
6. Install oil tube fixture (T34) (5), two 1/4 x 28
bolts (6), and 1/4 x 28 nuts (7) on nozzle flange
(8) at the 12-oclock position.
7. Thread reducer, P/N 2-141-121-04 (9) into lube-
in adapter (10) until adapter (10) is firmly seated
in oil tube fixture (T34) (5).