REPAIR SECOND TURBINE NOZZLE, SPACER, AND CASE (AVIM) (Continued)
4-60
NOTE
In following step, difficulty may be en-
countered when removing cover due to
tight fit of cover around air diffuser as-
sembly. The tight fit is necessary to
ensure that machining chips do not
enter air diffuser assembly.
41. Remove spring (12) and cover (11).
42. Use vacuum cleaner to remove metal particles.
43. Install three bolts (3). Lockwire bolts (3). Use
lockwire (E29).
INSPECT
GO TO NEXT PAGE