TM 55-2840-254-23
2-8.1 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITH WATER WASH KIT
2-8.1
P/N 2-200-071-54 INSTALLED) (Continued)
17. Place fingers over two port openings on tee
(18). Check clearance between bleed band
(24) and compressor housing (22) at 12-,5-,
and 8-oclock positions. Use thickness gage.
Clearance shall not be more than 0.002-inch
drag fit. If fit is too loose, proceed as follows:
a. Check bleed band (24) for twists, kinks,
and dirt or other deposits on side that goes
against compressor housing (22). Replace
bleed band (24) if twisted or kinked (Ref.
Task 2-9 and 2-13).
GO TO NEXT PAGE
2-40.8
C h a n g e
5