Figure 5. Tightening Position of Wrench
Figure 6. Cable Clamps - Strain Reliefs M85049/1-20B (Sheet 1 of 2)

Installation and Repair Practices Volume II Aircraft Circular Connectors and Accessories
Page Navigation
  617    618    619    620    621  622  623    624    625    626    627  
img
NAVAIR 01-1A-505-2
007 03
TO 00-25-255-1
Page 9
TM 1-1500-323-24-2
radio frequency interference from other equipment. A
11. CONNECTOR ACCESSORIES, SOLDER
physical and electrical shield is employed which is
CONTACT TYPE.
terminated at one or both ends to a ground or some
other predetermined point with respect to ground.
12. Connector accessories to enhance solder type
Shields can be applied to individual wires, cables,
contact connectors are as follows:
bundles, and harness.
a.
Cable Clamps/Strain Reliefs.
17. BONDING RINGS. Bonding rings are used with
cable clamps or flexible conduit coupling nuts to ground
b.
EMI-RFI and Grounding Terminators.
wire shielding (Figure 10).
c.
Bonding Rings.
18. Bonding Ring Installation. Bonding rings are
installed using the following procedure:
d.
Mounting Plates for Flange Mount Receptacles.
a.  Separate shield from each wire at end of cable
13. CABLE CLAMPS/STRAIN RELIEFS. The following
by pulling wire through a hole pierced in the shield.
two paragraphs explain the two types of cable support
or clamping devices.
b.
Gather individual wire shield together.
14. Cable CIamps. A cable clamp is a support or
c.
Crimp shields in bonding ring tongue and
clamping device which requires use of an intermediate
solder.
component for attachment to back of connector
(Figures 6, 7, 8 and 9).
d.  Tighten cable clamp or coupling nut to end of
bell of connector.
15. Strain Reliefs. A strain relief is a support or clamping
device which attaches directly to connector (Figures 6,
19. MOUNTING PLATES FOR FLANGE MOUNT
7, 8 and 9).
RECEPTACLES. Mounting plates are used to secure a
flange mount receptacle to mounting structure.
16. EMI/RFI GROUNDING TERMINATORS. EMI/
Mounting plates are available in heavy, medium, and
RFI grounding terminators are used to ground or shield
light duty type (Figures 11, 12 and 13).