10. Modifier. To determine the modifier, refer to Table
d. Type: F fixed socket. Fixed actuating member
1 and Figure 2, such as: M28731/10-0109-C where
with a female thread (engages with a type C or G
"M28731/10" is the "-0109" denotes the modifier.
jackscrew).
11. Mounting Type. The mounting type denotes the
e. Type: G jackscrew. Rotatable actuating member
connector mounting configuration. To determine the
with a male thread (engages with a type F fixed socket).
type, refer to table 1 and figure 2., such as: M28731/10-
Actuating knob is for hand tightening only.
0109-C where "-C" denotes the type..
12. Mounting types describe the actuating hardware
f. Type: H jacksocket. Rotatable actuating member
design. To aid in the engagement of connectors,
with a female thread (engages with type E fixed screw).
actuating hardware
Actuating knob includes a screwdriver slot.
shall be used as required. This hardware shall be
categorized as follows and be denoted by their associated
13. DESIGN AND CONSTRUCTION. Connectors
type, refer to table 1.
and accessories are designed and constructed to
withstand normal handling incidental to installation and
a. Type: C jackscrew. Rotatable actuating member
maintenance.
with a male thread (engages with a type F fixed socket).
The actuating knob includes a screwdriver slot.
14. INSERTS. Inserts are of diallyl phthalate material
molded one-piece construction, having electrical and
b. Type: D jack socket. Rotatable actuating member
mechanical characteristics suitable for the purpose
with a female thread (engages with a type E fixed screw).
intended. The impact strength shall be such that material
shall not chip, crack, or break during assembly, or
c. Type: E fixed screw. Fixed actuating member
normal maintenance.
with a male thread (engages with a type D or H jack
socket).
15. INTERCHANGEABILITY. All connectors having
the same military part number shall be completely
interchangeable with respect to installation and
performance. All contacts shall be intermateable.