The  insulation  of  a
Modified
connection:
(not
Standard
connection:
connection made on the second level may overlap
modified): The standard wrapping
the last turn of the connection wrapped on level
bit wraps only the stripped part of
one. The modified wrapping bit will wrap one turn
the wire on the terminal.
of insulation at the base of the connection.
The modified C.S.W. bits cut the wire, strip the
insulation and wrap the wire in one operation.
Figure 12. Wire Wrapping Methods
Correct Routing
Incorrect Routing
Figure 13. Wire Wrap Routing
The simple rules of wire wrapping
1. Only two connections on the same terminal
(Level 3 is kept as a reserve for change and
repair).
2. Wrap both ends of a wire on the same level.
3. Wrap long wires first.
4. Removal of connections: simply unwrap and
do not reuse the unwrapped wire.
Figure 14. Wire Wrapping Simple Rules