NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
004 03
1 September 2011
Page 2
shield must be removed. Remove shield in accordance
with following procedure:
a. Loosen cable clamp and, if installed, strain
Wires can be pinched between metal
relief clamp.
parts. Ensure no wires are between metal
parts before tightening, and while
b. Remove four screws from either the side or
tightening any hardware.
bottom.
b. Tighten four screws from either the side or
c. Remove shield.
bottom.
9. SHIELD INSTALLATION. Upon completion of
c. Tighten cable clamp and, if used, strain
maintenance or modification, the shield must be
relief clamp.
replaced. Install shield in accordance with the following
procedure:
10. STRAIN RELIEF CLAMPS. Strain relief
clamps are used to prevent tension on the cable
a. Position shield on cable and connector.
from being transferred to the wire terminations.
(Figure 5).
Used On M28731/9 Thru M28731/18 And M28731/29 Thru M28731/34
Material: Cast Aluminum Alloy #380
Cover With .820 X .614 Cable Clamp
Cover With 1.000 X .800 Cable Clamp
Cover With 1.100 X 1.085 Cable Clamp
Figure 1. Aluminum Shield (Sheet 1 of 2)