NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
012 02
1 September 2011
Page 12
Contact Inspection Hole
Insulation Gap
Contact Size
Wire AWG
Insulation Gap
20
1/32" MIN
16
18
5/64" MAX
16
Figure 11. Insulation Gap
36. Moisture Barrier. For connector sealing
procedures, including application of sealant to
grommet sealed connectors refer to NAVAIR 0l-lA-
505-1, WP 025 00.
37. CONTACT REMOVAL. Remove wired,
unwired, and broken wire contacts in accordance with
following procedures:
38. Wired Contact Removal.
Figure 12. Inserting Contact into Insertion Tool
34. CONNECTOR SEALING.
35. Sealing Plugs. Seal connector in accordance with
following procedure:
a. Fill all unused cavities with un-crimped
contacts (Paragraph 34).
b. Insert M85028/4 sealing plug, small diameter
first, until bottomed in contact cavity (Figure 14). Do
not insert further than knob. Fill all cavities that have
Figure 13. Contact Insertion
un-crimped contacts.