3. SAS STALL Switches -- One at a Time to
Stall
a. Note Green ADV Lights on SAS gauge
4. POWER LEVERS -- SET Ground Idle
5. SAS STALL Switches -- SET Both to Stall
a. Check Shakers, L & R Stall Lights, Stall
Horn On -- NO PUSHER
6. SAS SERVO Switch -- ON
a. Check SAS Servo Fail Light Out
7. STALL LIGHT Left Switch -- PUSH
a. L SAS FAIL Light On
8. SAS Gauge Select Switch -- SELECT Left
Side
a. Note Needle Position
9. SAS STALL Switches -- PUSH Both to Stall
a. Check Shaker, R STALL Light and Stall
Horn On -- NO PUSHER
10. STALL LIGHT Left Switch -- PUSH L SAS
Fail Light Out
11. STALL LIGHT Right Switch -- PUSH R SAS
Fail Light On
12. SAS Gauge Select Switch -- SELECT Right
Side
a. Note Needle Position
13. SAS STALL Switches -- PUSH Both to Stall
a. Check Shaker, L STALL Light and Stall
Horn On -- NO PUSHER
14. STALL LIGHT Right Switch -- PUSH
a. R SAS Fail Light Out
15. SAS STALL Left Switch -- PUSH To Stall
a. Check Shaker, L STALL Light and Stall
Horn On -- NO PUSHER
16. SAS STALL Right Switch -- PUSH To Stall
a. Check Shaker, R STALL Light and Stall
Horn On -- NO PUSHER