TM 1-1510-253-CL
NOTE
Changes in EGT between engines SRL OFF
and ON must not exceed 10C. If 10C is ex-
ceeded, SRL system must be checked or cor-
rected before further flight or operations must
be conducted in accordance with SRL Inoper-
ative procedures.
9. Left SRL
P/P POWER Switch --
SELECT Normal
10. TEMP LIMITER TEST Switch -- SELECT L
(Left)
NOTE
Do not let RPM decay below 90% RPM.
11. TEMP LIMITER TEST Switch -- RELEASE
a. Note an increase in EGT, RPM, and FUEL
FLOW, and FUEL BYPASS OPEN Light
extinguished
12. Left POWER LEVER -- SELECT GROUND
IDLE
13. Left Speed Lever -- SET Low RPM
a. Repeat steps 3 13 for right engine
NOTE
If temp limiter fails, pull temp limiter circuit
breaker. Operate engine in accordance with
procedures outlined in Temperature Limiter
Malfunctions section of FLIGHT MANUAL.
HIGH RESIDUAL EGT START
Whenever an engine ground start is required soon after
engine shutdown while residual EGT is above 200 C, the
following procedure is recommended:
1. COMPLETE all Before Starting Engine
Checks.
2. COMPLETE all Starting Engine Checks up
to Engine Start.
P-17