TM 1-1520-253-23
Table 1-2. Access Panels, Doors, and Fairings - Continued
Item No.
Item
Access To
28
Panel
Aft landing gear
29
Panel
Aft ground test connections
30
Door
Combiner transmission
31
Door
Forward transmission hyd.module
32
Panel
Flight controls closet
33
Cover
Aft driveshafting
34
Baffle
Aft transmission
35
Door
Rescue hatch
36
Panel
37
Door
Aft pylon mounting bolts
38
Door
Hyd bay access
39
Door
Aft transmission and blower
40
Door
Radar warning receiver
41
Cover
Area between forward pod fairing and fuel pod
42
Covers
Area between fuel pod and aft pod fairing
WARNING
To prevent injury to personnel and damage to helicopter, stand only on designated surfaces.
These areas are reinforced to withstand frequent use and are treaded to prevent slipping. All other
surfaces are NO STEP areas.
1.2.7 Steps. Handholds and Walkways Steps, handholds, and walkways aid in
performing maintenance, inspections,
and servicing on helicopters.
1.3. MARKING AND/OR RECORDING OF
INSPECTION RESULTS.
NOTE
Only approved marking pencils are to be used for temporary marking of indications found during
an NDI inspection. The color of the marking shall contrast with the color of the part.
a. Wipe the area to be marked with low-lint cleaning cloth, MIL-C-85043.
b. Mark surface with appropriate color aircraft marking pencil, MIL-P-83953, using a light touch.