TM 10-4930-351-14
0012 00
Table 1. Operator Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. Leakage at discharge end of nozzle during refueling.
Step 1.
Stop refueling operation, disconnect nozzle from adapter.
Step 2.
Inspect nozzle discharge end for foreign matter.
Remove foreign matter and wipe with a clean rag.
Step 3.
Notify unit maintenance if still leaks.
13. Leakage between nozzle inlet coupling and hose coupling.
Step 1.
Relieve fuel pressure on hose, shut off fuel flow to hose.
Step 2.
Inspect coupling connection for damage.
Notify unit maintenance if damaged.
Step 3.
Disconnect nozzle from hose.
Step 4.
Inspect coupling gasket for damage.
Notify unit maintenance if damaged.
Step 5.
Check for leaks after cleaning both ends of Coupling Assembly and reconnecting nozzle to hose.
Notify unit maintenance if still leaks.
14. Fuel drum leaks at adapter assembly.
Step 1.
Check for looseness.
Tighten as required.
Step 2.
Check adapter assembly for damage.
Notify unit maintenance if damaged.
15. Cargo in TRICON is damaged by weather.
Step 1.
Inspect exterior of container for holes or cracks that exist in exterior panels or at welds.
If holes, cracks, and broken welds are found, notify your supervisor.
Step 2.
Inspect seals along door edges for signs of wear or deterioration.
If seals need replacing, notify your supervisor.
16. Cargo in TRICON is damaged by movement.
Inspect tie-downs for broken welds.
If tie-downs have broken welds, it must be repaired. Notify your supervisor.
0012 00-3