Table 1. Operator Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
17. TRICON door does not close.
Step 1.
Check for any cargo or debris interfering with the door closing.
Move cargo so it clears door and remove any debris.
Step 2.
Check both doors for severe warpage or distortion.
If damage exist, doors may need replacement. Notify your supervisor.
Step 3.
Check door frame for bent or damaged areas.
If damage exist, major repair is needed. Notify your supervisor.
18. TRICON door does not open.
Step 1.
Verify that all lockrod assembly handles can be raised from their latches and pulled outward.
If lockrod assembly is damaged, replacement is needed. Maintenance at a higher level is needed.
Notify your supervisor.
Step 2.
Check for proper door operation after all lockrod assembly handles are pulled outward.
Improper operation can be the result of damaged hinges or bent frame. Notify your supervisor.
19. Documents in document holder of TRICON are damaged.
Step 1.
Inspect document holder for any apparent damages.
Notify unit maintenance if holder is damaged.
Step 2.
Check document holder for proper operation
Notify unit maintenance if holder is operating properly.
20. TRICON containers can not be coupled.
Step 1.
Using the connecting link assembly, check for damaged container corners.
If connecting link assembly does not fit properly or could be remove when locked, corner is damaged.
Notify your supervisor.
Step 2.
Replace damaged connecting link assembly.