TM 10-4930-351-14
0013 00
Table 1. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TRICON CONTAINER
1. Documents in TRICON are damaged.
Step 1. Inspect document holder for any apparent damages.
Step 2. Check document holder for proper operation
2. Cargo is damaged by weather.
Inspect seals along door edges for signs of wear or deterioration.
PRESSURE CONTROL
1. Pressure Control coupling halves leak.
Inspect for damaged or missing gasket.
2. Fuel appears on Pressure Control body between two main castings
Step 1. Inspect for broken pilot valve bellows assembly.
Step 2. Inspect for damaged preformed packing in pilot valve.
Step 3. Inspect for damaged venturi preformed packing.
Step 4. Inspect venturi throat for damage.
3. Diaphragm Valve fails.
Step 1. Inspect for ruptured diaphragm.
Step 2. Inspect for compression ring damage.
4. Pressure Control shuts off prematurely or too late.
Check pilot valve adjustment.
0013 00-8