TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPLACE TRICON SEAL SET
INITIAL SET-UP:
Materials/Parts Required:-Continued
Tools:
Materials/Parts Required:
Equipment Condition:
Sealant, Polyurethane
Both doors open.
Personnel Required:
Two
REMOVAL
WARNING
To gain access to the seals on the bottom door edge, it may be necessary to raise the
container above floor level. Use lifting devices rated for a minimum of 10,000
pounds (4536 Kg). Using less than rated equipment could expose personnel to
serious injury or death.
NOTE
Removal of the seals is the same for both left- and right-hand doors.
1.
Using a 3/16" drill bit drill out rivets (figure 1, 1). There are seven rivets on each top and bottom edge and 14 rivets on
each side edge. The left-hand door does not have rivets on the edge that mates with the right-hand door.
2.
Remove and discard all short carriers (figure 1, 2) and long carriers (3). The right-hand door has carriers on all four door
edges. The left-hand door does not have a carrier or seal on the edge that mates with the right-hand door.
2
1
3
Figure 1. Left-Hand Door Seals and Carriers Removal