TM 10-4930-351-14
0033 00
ASSEMBLY
WARNING
Rubber gloves should be worn when handling fueling system components due to the
toxic effects of some fuel additives.
1.
If removed, install locking pin (10) and spring (11).
2.
Install lugs (7 and/or 8) with screws (9).
1
4
5
2
9
11
10
7
6
12
8
13
9
4
3
3.
Install bumper (6) onto coupling body with the tapered edge facing the unisex coupling (2) body.
4.
Attach cable (4) to dust cap (3) by looping about 6 inches of cable through the hole in dust cap (3) forming a loop back
on the cable (4). Install and crimp a sleeve (13) over the two sections of cable (4).
5.
If cable (4) was cut, attach cable (4) to split ring (5) by looping about 6 inches of cable through the ring (5) forming a
loop back on the cable (4). Install and crimp a sleeve (13) over the two sections of cable (4). If cable (4) was not cut,
attach to split ring (5) by rotating split ring (5) through cable (4) loop.
6.
Install spring (1) in unisex coupling (2).
END OF WORK PACKAGE