6-26. Accumulator - Installation - Continued
ENGINE/ - Continued
8. Elbow (15)
Hold with backup
wrench and loosen nut
(16). Loosen clamp
so accumulator (13)
and assembly may be
turned. Leave assem-
bly loose and continue
installation.
9. clamp (4)
10. New preformed
packing (6)
11. Accumulator (5)
12. Nut on base (2)
13. clamp (1)
14. Union (4)
NOTE
Do not lubricate preformed
packing,
Install on check valve
(10). Attach clamp to
fireshield using bolt,
spacer, washer and nut.
Do not tighten.
Place on accumulator
(5).
Screw on elbow (7).
Hold backup wrench
on elbow and tighten
accumulator 55-80 in.
lb (0.6-0.9 kg/m) by
turning on the hexag-
onal surface on the
accumulator adjacent
to the elbow.
Install to union (3).
Do not tighten.
Adjust and tighten
clamping nut to 35-40
in. lb (0.4-0.5 kg/m).
Hold with backup
wrench. Tighten nut
on hose (2) to 80-120
in. lb (0.9-1.4 kg/m).
6-63