9-6. Compressor Bleed Valve-Testing
INITIAL SETUP
Applicable Configuration
Equipment Condition
All
Bleed Valve must be on engine
NOTE
(For OH-6A AIRCRAFT) Replace
OH-6A elbow jet assembly (4) with
a standard elbow (3) prior to
testing. The bleed valve operation
figure DOES NOT APPLY when jet
assembly (4) is installed. Reinstall
OH-6A jet assembly (4) when
testing is completed. Retain
standard elbow for future use.
OH-58A aircraft shall have the
standard elbow (3) installed.
ENGINE/
1. Bleed Valve
2. Jet Assembly (4)
Jet assembly (4) must be
removed and replaced
with a standard elbow
fitting (3) prior to testing.
Turn off all bleed air.
Change 11