TM55-2840-251-23
6-7
FUEL NOZZLES (AVIM) (Continued)
6-7-1 CLEANING (Cont)
7. Connect hot tapwater hose to fixture and flush very
hot water at tap pressure for at least one minute.
8.
Disconnect water supply.
9.
Connect
fixture
to
supply
of
clean,
filtered
compressed air. Insure nozzles are thoroughly dry.
10. With nozzles still installed in fixture, connect fixture
to Test Rig (T.37) and flow fuel through nozzles for one
minute at 30 psig.
11. Remove fixture from test rig and nozzles from
fixture.
NOTE
If nozzles are not required for immediate
installation, store in covered container to
prevent exposure to dirt.
6-7-2 INSPECTION
Inspect components for signs of obvious damage.
No damage permitted.
FOLLOW ON MAINTENANCE:
Installation Fuel Nozzles into
Adapters (Task 6-6-4)
END OF TASK
6-35/(6-36 blank)