TM 55-2840-254-23
2-15 CLEAN ANTI-ICING AIR GALLERY COVER
2-15
INITIAL SETUP
Applicable Configurations:
AlI
Tools:
Powerplant Mechanics Tool Kit,
NSN 5180-00-323-4944
Putty Knife
Materials:
Dry Cleaning Solvent (E17)
Gloves (E20)
Lint-Free Cloth (E26)
Personnel Required:
68B10 Aircraft Powerplant Repairer
Equipment Condition:
Off Engine Task
Oil Cooler Assembly Removed (Task 8-5)
Interstage Air-Bleed Actautor Removed
(Task 2-1)
Dual Chip Detector Removed (Task 8-28)
Fuel Control Removed (Task 6-1)
Main Fuel Filter and Bracket Removed
(Task 6-29)
Anti-Icing Air Gallery Cover Removed
(Task 2-14)
GO TO NEXT PAGE
General Safety Instructions:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate akin end cause
burns. Use only in well-ventilated area,
away from heat and open flame. In
case of contact, immediately flush skin
or eyes with water for et least 15 minutes.
Get medical attention for eyes.
2-55