TM 55-2840-254-23
2-21 CLEAN COMPRESSOR HOUSING
2-21
INITIAL SETUP
Applicable Configurations:
All
Tools:
Powerplant Mechanics Tool
NSN 5180-00-323-4944
Goggles
Compressed Air Source
Fiber Brush
Materials:
Dry Cleaning Solvent (E17)
Gloves (E20)
Personnel Rewired:
Ignition Exciter Removed (Task 7-11)
Oil Filler Assembly and Oil Filler Strainer Re-
moved (Task 8-16) (Upper Compressor
Housing Only)
Starter Drive Assembly Removed (Task 5-12)
(Upper Compressor Housing Only)
Kit,
Main Fuel Filter and Bracket Removed
(Task 6-29)
Dual Chip Detector Removed (Task 8-28)
(Lower Compressor Housing Only)
Fuel Boost Pump Assembly Removed
(Task 6-9) (Lower Compressor Housing
Only)
Tube Assembly (Inlet Housing to Main Oil
Pump Removed (Task 8-50) ( Lower
Compressor Housing Only)
Main Oil Pump and Scavenqe Oil Screen Re-
68B10 Aircraft Powerplant Repairer
moved (Task 8-1 ) (Lower Compressor
Housing Only)
Equipment Condition:
Fuel Control Removed (Task 6-1) ( Lower
Engine Oil System Drained (Task 1-75)
Compressor Housing Only)
Oil Cooler Assembly Removed (Task 8-5)
Accessory Gearbox Removed (Task 5-1)
In-Line Fuel Filter Assembly Removed
(Lower Compressor Housing Only)
(Task 6-36)
Interstage Air-Bleed Actuator Removed
(Task 2-1)
Compressor Bleed Band Removed (Task
2-9)
Compressor Housing Removed (Task 2-19
or 2-20)
General Safety Instructions:
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or
eyes with water for at least 15 minutes.
Get medical attention for eyes.
GO TO NEXT PAGE
2-144