TM 55-2840-254-23
Section II. COMBUSTION SECTION AND POWER TURBINE - MAINTENANCE PROCEDURES
3-5 REMOVE COMBUSTION SECTION AND POWER TURBINE (AVIM)
3-5
INITIAL SETUP
Applicable Configurations.
All
Tools:
Powerplant Mechanics Tool Kit,
NSN 5180-00-323-4944
Group Aircraft Cover (T24)
Clamp Coupling Half (T37)
Open-End Wrench (T53)
Power Turbine Fixture (T54)
Hoist
Materials:
Marking Pencil (E34)
Vexar Nylon Webbing (E56)
Personnel Required:
68B10 Aircraft Powerplant
Repairer (2)
References:
Task 3-8
Equipment Condition:
Engine Oil System Drained (Task 1-75)
The ignition exciter stores very
high and possibly fatal voltage.
Use extreme care when working
around ignition exciter. Serious
injury could result if exciter is
accidentally grounded. Do not probe
inside of output receptacles with
fingers or metal objects. Discharge
exciter only with insulated screw-
driver. In case of shock or injury,
get medical attention.
GO TO NEXT PAGE
Change 3
3-11